Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 958
Filtrar
1.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 42(1): 13-16, Ene. 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-229213

RESUMO

Introducción: La carga viral es un marcador muy útil para realizar el seguimiento de los pacientes infectados por VHB y VHC. Este trabajo compara ensayos basados en amplificación mediada por transcripción y en PCR a tiempo real con el objetivo de comprobar si pueden ser intercambiables. Material y métodos: Estudio bicéntrico en el que se analizó la carga viral de 147 muestras de plasma de pacientes infectados por VHB y 229 por VHC, mediante ensayos basados en amplificación mediada por transcripción (Aptima® HBV Quant y Aptima® HCV Quant Dx, que utilizan el sistema Panther (Hologic®)) y PCR a tiempo real (COBAS® AmpliPrep / COBAS® TaqMan® y COBAS® 6800), calculando el grado de concordancia entre ellos. Resultados: Se detectó carga viral en ambos equipos en 60 (40,82%) muestras de VHB (mediana del log de la carga viral: COBAS®: 2,51UI/mL (RIC 2,20-3,17), Panther: 2,71UI/mL (RIC 2,21-3,22)) y en 39 (16,96%) muestras de VHC (mediana del log de la carga viral: COBAS®: 3,93UI/mL (RIC 2,24-6,01), Panther: 3,80UI/mL (RIC 1,99-6,14)). La concordancia entre ambos equipos fue de κ=0,943 para VHB y κ=0,925 para VHC. La comparación de las muestras con carga viral detectada mediante los 2 ensayos mostró una correlación alta tanto para VHB (R2=0,86) como para VHC (R2=0,97). Conclusiones: Los ensayos basados tanto en amplificación mediada por transcripción como en PCR a tiempo real pueden ser intercambiables para el manejo de pacientes infectados con VHB y VHC.(AU)


Introduction: Viral load is a very useful marker for monitoring patients infected with HBV and HCV. This work compares assays based on transcription-mediated amplification and on real-time PCR to verify whether they can be interchangeable. Material and methods: a bicentric study, in which 147 plasma samples from patients infected with HBV and 229 with HCV were analyzed, was carried out. Transcription-mediated amplification-based assays (Aptima® HBV Quant and Aptima® HCV Quant Dx, employing Panther system (Hologic®)) and on real-time PCR (COBAS® AmpliPrep / COBAS® TaqMan® and COBAS® 6800) were used and the degree of concordance between them was calculated. Results: Viral load was detected in both systems in 60 (40.82%) HBV samples (median log viral load: COBAS®: 2.51IU/mL (IQR 2.20-3.17), Panther: 2.71IU/mL (IQR 2.21-3.22)) and in 39 (16.96%) HCV samples (median log viral load: COBAS®: 3.93IU/mL (IQR 2.24-6.01), Panther: 3.80IU/mL (IQR 1.99-6.14)). The agreement between both systems was κ=0.943 for HBV and κ=0.925 for HCV. Comparison of viral load samples detected by both assays showed a hight correlation for HBV (R2=0.86) and for HCV (R2=0.97). Conclusions: Both transcription-mediated amplification and on real-time PCR based assays may be interchangeable for the management of patients infected with HBV and HCV.(AU)


Assuntos
Humanos , Masculino , Feminino , Vírus da Hepatite B , Hepacivirus/genética , Plasma/virologia , Carga Viral , Reação em Cadeia da Polimerase em Tempo Real , Microbiologia , Técnicas Microbiológicas , Reação em Cadeia da Polimerase
2.
Antiviral Res ; 197: 105212, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34838583

RESUMO

Drug repositioning has been used extensively since the beginning of the COVID-19 pandemic in an attempt to identify antiviral molecules for use in human therapeutics. Hydroxychloroquine and azithromycin have shown inhibitory activity against SARS-CoV-2 replication in different cell lines. Based on such in vitro data and despite the weakness of preclinical assessment, many clinical trials were set up using these molecules. In the present study, we show that hydroxychloroquine and azithromycin alone or combined does not block SARS-CoV-2 replication in human bronchial airway epithelia. When tested in a Syrian hamster model, hydroxychloroquine and azithromycin administrated alone or combined displayed no significant effect on viral replication, clinical course of the disease and lung impairments, even at high doses. Hydroxychloroquine quantification in lung tissues confirmed strong exposure to the drug, above in vitro inhibitory concentrations. Overall, this study does not support the use of hydroxychloroquine and azithromycin as antiviral drugs for the treatment of SARS-CoV-2 infections.


Assuntos
Anti-Infecciosos/farmacologia , Azitromicina/farmacologia , Tratamento Farmacológico da COVID-19 , Hidroxicloroquina/farmacologia , SARS-CoV-2/efeitos dos fármacos , Animais , Anti-Infecciosos/administração & dosagem , Anti-Infecciosos/uso terapêutico , Azitromicina/administração & dosagem , Azitromicina/farmacocinética , Azitromicina/uso terapêutico , Brônquios/citologia , Brônquios/virologia , Chlorocebus aethiops , Cricetinae , Modelos Animais de Doenças , Quimioterapia Combinada , Feminino , Humanos , Hidroxicloroquina/administração & dosagem , Hidroxicloroquina/uso terapêutico , Pulmão/patologia , Mesocricetus , Pessoa de Meia-Idade , Plasma/virologia , Reação em Cadeia da Polimerase em Tempo Real , Células Vero
3.
JAMA Netw Open ; 4(7): e2116572, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34251441

RESUMO

Importance: Seroprevalence studies complement data on detected cases and attributed deaths in assessing the cumulative spread of the SARS-CoV-2 virus. Objective: To estimate seroprevalence of SARS-CoV-2 antibodies in patients receiving dialysis and adults in the US in January 2021 before the widespread introduction of COVID-19 vaccines. Design, Setting, and Participants: This cross-sectional study used data from the third largest US dialysis organization (US Renal Care), which has facilities located nationwide, to estimate SARS-CoV-2 seroprevalence among US patients receiving dialysis. Remainder plasma (ie, plasma that would have otherwise been discarded) of all patients receiving dialysis at US Renal Care facilities from January 1 to 31, 2021, was tested for SARS-CoV-2 antibodies. Patients were excluded if they had a documented dose of SARS-CoV-2 vaccination or if a residence zip code was missing from electronic medical records. Crude seroprevalence estimates from this sample (January 2021) were standardized to the US adult population using the 2018 American Community Survey 1-year estimates and stratified by age group, sex, self-reported race/ethnicity, neighborhood race/ethnicity composition, neighborhood income level, and urban or rural status. These data and case detection rates were then compared with data from a July 2020 subsample of patients who received dialysis at the same facilities. Exposures: Age, sex, race/ethnicity, and region of residence as well as neighborhood race/ethnicity composition, poverty, population density, and urban or rural status. Main Outcomes and Measures: The spike protein receptor-binding domain total antibody assay (Siemens Healthineers; manufacturer-reported sensitivity of 100% and specificity of 99.8%) was used to estimate crude SARS-CoV-2 seroprevalence in the unweighted sample, and then the estimated seroprevalence rates for the US dialysis and adult populations were calculated, adjusting for age, sex, and region. Results: A total of 21 464 patients (mean [SD] age, 63.1 [14.2] years; 12 265 men [57%]) were included in the unweighted sample from January 2021. The patients were disproportionately older (aged 65-79 years, 7847 [37%]; aged ≥80 years, 2668 [12%]) and members of racial/ethnic minority groups (Hispanic patients, 2945 [18%]; non-Hispanic Black patients, 4875 [29%]). Seroprevalence of SARS-CoV-2 antibodies was 18.9% (95% CI, 18.3%-19.5%) in the sample, with a seroprevalence of 18.7% (95% CI, 18.1%-19.2%) standardized to the US dialysis population, and 21.3% (95% CI, 20.3%-22.3%) standardized to the US adult population. In the unweighted sample, younger persons (aged 18-44 years, 25.9%; 95% CI, 24.1%-27.8%), those who self-identified as Hispanic or living in Hispanic neighborhoods (25.1%; 95% CI, 23.6%-26.4%), and those living in the lowest-income neighborhoods (24.8%; 95% CI, 23.2%-26.5%) were among the subgroups with the highest seroprevalence. Little variability was observed in seroprevalence by geographic region, population density, and urban or rural status in the January 2021 sample (largest regional difference, 1.2 [95% CI, 1.1-1.3] higher odds of seroprevalence in residents of the Northeast vs West). Conclusions and Relevance: In this cross-sectional study of patients receiving dialysis in the US, fewer than 1 in 4 patients had evidence of SARS-CoV-2 antibodies 1 year after the first case of SARS-CoV-2 infection was detected in the US. Results standardized to the US population indicate similar prevalence of antibodies among US adults. Vaccine introduction to younger individuals, those living in neighborhoods with a large population of racial/ethnic minority residents, and those living in low-income neighborhoods may be critical to disrupting the spread of infection.


Assuntos
Diálise/estatística & dados numéricos , SARS-CoV-2 , Estudos Soroepidemiológicos , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , COVID-19/virologia , Estudos Transversais , Diálise/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plasma/virologia , Inquéritos e Questionários , Estados Unidos/epidemiologia
4.
Vet Res ; 52(1): 91, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34158102

RESUMO

Understanding the mechanisms of transmission of infectious laryngotracheitis virus (ILTV) is critical to proper control as both vaccine and wild-type strains circulate within chicken flocks with potential adverse consequences. The relative efficiency of transmission by direct contact between chickens and airborne transmission has not been investigated. Furthermore, relatively high levels of ILTV DNA have been detected in poultry dust and blood but the infectivity of these is unknown. In this study, comparison of in-contact and airborne transmission of two vaccine and one field strain of ILTV revealed that all transmitted to 100% of in-contact birds by 6 days post-exposure (dpe). Airborne transmission without contact resulted in 100% transmission by 14 and 17 dpe for the wild-type and Serva vaccine virus but only 27% transmission by 21 dpe for the A20 vaccine virus. The infectivity of dust or extracts of dust and blood or plasma from infected chickens at various stages of infection was assessed by inoculation into susceptible chickens. There was no transmission by any of these materials. In conclusion, direct contact facilitated efficient ILTV transmission but the virus was unable to be transmitted by dust from infected chickens suggestive of a limited role in the epidemiology of ILTV.


Assuntos
Poeira , Infecções por Herpesviridae/veterinária , Herpesvirus Galináceo 1/fisiologia , Vacinas contra Herpesvirus/efeitos adversos , Doenças das Aves Domésticas/transmissão , Animais , Sangue/virologia , Galinhas , Infecções por Herpesviridae/transmissão , Infecções por Herpesviridae/virologia , Abrigo para Animais , Plasma/virologia , Doenças das Aves Domésticas/virologia , Replicação Viral
5.
Biologicals ; 71: 9-19, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34006447

RESUMO

The European Directorate for the Quality of Medicines & HealthCare (EDQM) has run proficiency testing schemes on the detection of viral contaminants in human plasma pools by nucleic-acid amplification techniques since 1999 for hepatitis C virus and since 2004 for parvovirus B19. A retrospective analysis was performed to assess their impact and identify trends and progress in the results obtained by participating laboratories over a 15-year span, from 2004 to 2018. The results demonstrate that overall performance improved over that time, especially among the regular participants. Participation in these proficiency testing schemes is therefore recommended for all interested control laboratories. This analysis also shows that hepatitis C virus detection now seems well established compared to that of parvovirus B19, which still appears more challenging.


Assuntos
Hepacivirus/isolamento & purificação , Parvovirus B19 Humano/isolamento & purificação , Plasma/virologia , Doadores de Sangue , DNA Viral/isolamento & purificação , Hepacivirus/genética , Humanos , Parvovirus B19 Humano/genética , Estudos Retrospectivos
6.
Cells ; 10(3)2021 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-33801959

RESUMO

We herein characterize the immunopathological features of two Italian COVID-19 patients who underwent bilateral lung transplantation (bLTx). Removed lungs underwent histopathological evaluation. Gene expression profiling (GEP) for immune-related signatures was performed on lung specimens and SARS-CoV-2-stimulated peripheral blood mononuclear cells (PBMCs). Cytokine levels were measured on lungs, bronchoalveolar lavage fluids and in culture supernatants. Pathological assessment showed extensive lung damage with the pattern of proliferative to fibrotic phases, with diffuse alveolar damage mimicking usual interstitial pneumonia (UIP). Lungs' GEP revealed overexpression of pathogen recognition receptors, effector cytokines and chemokines, immune activation receptors and of the inflammasome components. Multiplex cytokine analysis confirmed a proinflammatory state, with high levels of monocyte/macrophage chemotactic and activating factors and of IL-6 and TNF-α. A similar profile was observed in SARS-CoV-2-stimulated PBMCs collected 7 days after transplant. The pattern of tissue damage observed in the lungs suggests that this may represent the output of protracted disease, resembling a diffuse UIP-like picture. The molecular immune profiling supports the paradigm of a persistent proinflammatory state and sustained humoral immunity, conditions that are maintained despite the iatrogenic immunosuppression.


Assuntos
COVID-19/cirurgia , Quimiocinas/metabolismo , Citocinas/metabolismo , Leucócitos Mononucleares/metabolismo , Transplante de Pulmão , Pulmão/patologia , Síndrome do Desconforto Respiratório/cirurgia , Adolescente , Líquido da Lavagem Broncoalveolar/citologia , Líquido da Lavagem Broncoalveolar/virologia , COVID-19/sangue , Perfilação da Expressão Gênica , Regulação da Expressão Gênica/imunologia , Genótipo , Humanos , Inflamassomos/metabolismo , Interleucina-6/metabolismo , Pulmão/imunologia , Pulmão/metabolismo , Pulmão/virologia , Linfonodos/patologia , Linfonodos/virologia , Masculino , Pessoa de Meia-Idade , Plasma/virologia , Polimorfismo de Nucleotídeo Único , Síndrome do Desconforto Respiratório/imunologia , Síndrome do Desconforto Respiratório/patologia , Síndrome do Desconforto Respiratório/virologia , Fator de Necrose Tumoral alfa/metabolismo
7.
BMC Infect Dis ; 21(1): 357, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33863281

RESUMO

BACKGROUND: In 2020, a new coronavirus, SARS-CoV-2, quickly spread worldwide within a few months. Although coronaviruses typically infect the upper or lower respiratory tract, the virus RNA can be detected in plasma. The risk of transmitting coronavirus via transfusion of blood products remains. As more asymptomatic infections are identified in COVID-19 cases, blood safety has become particularly important. Methylene blue (MB) photochemical technology has been proven to inactivate lipid-enveloped viruses with high efficiency and safety. The present study aimed to investigate the SARS-CoV-2 inactivation effects of MB in plasma. METHODS: The SARS-CoV-2 virus strain was isolated from Zhejiang University. The live virus was harvested from cultured VERO-E6 cells, and mixed with MB in plasma. The MB final concentrations were 0, 1, 2, and 4 µM. The "BX-1 AIDS treatment instrument" was used at room temperature, the illumination adjusted to 55,000 ± 0.5 million Lux, and the plasma was irradiated for 0, 2, 5, 10, 20, and 40 mins using light at a single wavelength of 630 nm. Virus load changes were measured using quantitative reverse transcription- PCR. RESULTS: BX-1 could effectively eliminate SARS-CoV-2 within 2 mins in plasma, and the virus titer declined to 4.5 log10 TCID50 (median tissue culture infectious dose)/mL. CONCLUSION: BX-1 is based on MB photochemical technology, which was designed to inactivate HIV-1 virus in plasma. It was proven to be safe and reliable in clinical trials of HIV treatment. In this study, we showed that BX-1 could also be applied to inactivate SARS-CoV-2. During the current outbreak, this technique it has great potential for ensuring the safety of blood transfusions, for plasma transfusion therapy in recovering patients, and for preparing inactivated vaccines.


Assuntos
Segurança do Sangue , COVID-19/prevenção & controle , COVID-19/terapia , Azul de Metileno/farmacologia , SARS-CoV-2/efeitos dos fármacos , Inativação de Vírus , Animais , Transfusão de Sangue , Chlorocebus aethiops , Humanos , Imunização Passiva , Plasma/virologia , RNA Viral , Células Vero , Soroterapia para COVID-19
8.
Diagn Microbiol Infect Dis ; 100(3): 115365, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33865070

RESUMO

We present the case of an inpatient with pneumonia and repeatedly negative nasopharyngeal SARS-CoV-2 testing. In such challenging cases, alternative diagnostic options include lower respiratory tract and plasma SARS-CoV-2 RNA testing, of which the latter may be particularly useful where bronchoscopy is deferred due to clinical factors or transmission risk.


Assuntos
COVID-19/diagnóstico , Plasma/virologia , SARS-CoV-2/isolamento & purificação , Adulto , Teste de Ácido Nucleico para COVID-19 , Humanos , Masculino , Nasofaringe/virologia , RNA Viral/genética , Manejo de Espécimes
9.
Arch Virol ; 166(2): 587-591, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33245437

RESUMO

In the present study, the utility of viral RNA isolated from whole blood over plasma for detection of dengue virus (DENV) was investigated in 80 samples referred for serotyping by DENV serotype-specific one-step real-time RT-PCR. DENV RNA was detected in 71.25% of the whole blood samples compared to 46.25% in the corresponding plasma samples. In secondary infections, DENV RNA was detected in 83.3% of whole blood samples, while it was detected in 40.5% of plasma samples (P = 0.0001). Non-structural protein 1 (NS1) antigen was detected in only 54.8% of the secondary infections. The detection rate of DENV RNA in whole blood is higher than in plasma. We suggest that one-step real-time RT-PCR using RNA from whole blood combined with an NS1 ELISA should be the choice for dengue diagnosis in dengue vaccine trials.


Assuntos
Vacinas contra Dengue/imunologia , Vírus da Dengue/genética , Dengue/sangue , Dengue/virologia , Plasma/virologia , RNA Viral/sangue , Anticorpos Antivirais/imunologia , Antígenos Virais/imunologia , Dengue/imunologia , Vírus da Dengue/imunologia , Humanos , Plasma/imunologia , RNA Viral/genética , Sensibilidade e Especificidade , Sorogrupo , Sorotipagem/métodos , Proteínas não Estruturais Virais/imunologia
10.
J Infect Dis ; 223(3): 462-470, 2021 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-32603416

RESUMO

BACKGROUND: Although adipose tissue has been proposed to harbor part of the human immunodeficiency virus 1 (HIV-1) reservoir, the influence of host characteristics, including sex and body mass index (BMI), on measures of HIV-1 persistence during antiretroviral therapy (ART) are incompletely understood. METHODS: We evaluated age, sex, BMI, waist circumference, years on ART, pre-ART HIV-1 RNA, pre-ART CD4+ T-cell count, and initial ART regimen with measures of HIV-1 persistence in blood (residual viremia, cellular HIV-1 DNA and RNA) in a cohort of 295 individuals with well-documented long-term virologic suppression (HIV-1 RNA <50 copies/mL) on ART (AIDS Clinical Trials Group study A5321). RESULTS: Men were more likely than women to have detectable plasma HIV-1 RNA by single-copy assay (52% vs 29%; P = .003), and the proportion of participants with detectable residual viremia increased in a stepwise fashion by BMI category (normal weight or underweight, 38%; overweight, 50%; and obese, 55%). ART regimen type was not associated with measures of HIV-1 persistence after controlling for ART duration. CONCLUSIONS: Sex and obesity are independently associated with residual viremia in people on long-term ART. Additional studies to confirm these relationships and to define the mechanisms by which sex and obesity affect HIV-1 persistence are needed to inform HIV-1 cure strategies.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Infecções por HIV/tratamento farmacológico , HIV-1 , Obesidade/complicações , Plasma/virologia , Viremia/virologia , Adulto , Antirretrovirais/uso terapêutico , Linfócitos T CD4-Positivos , Estudos Transversais , DNA Viral/sangue , Feminino , HIV-1/genética , Humanos , Masculino , Pessoa de Meia-Idade , RNA Viral/sangue
11.
Vox Sang ; 116(6): 673-681, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33277935

RESUMO

BACKGROUND AND OBJECTIVES: During the ongoing pandemic of COVID-19, SARS-CoV-2 RNA was detected in plasma and platelet products from asymptomatic blood donors, raising concerns about potential risk of transfusion transmission, also in the context of the current therapeutic approach utilizing plasma from convalescent donors. The objective of this study was to assess the efficacy of amotosalen/UVA light treatment to inactivate SARS-CoV-2 in human plasma to reduce the risk of potential transmission through blood transfusion. METHODS: Pools of three whole-blood-derived human plasma units (630-650 ml) were inoculated with a clinical SARS-CoV-2 isolate. Spiked units were treated with amotosalen/UVA light (INTERCEPT Blood System™) to inactivate SARS-CoV-2. Infectious titres and genomic viral load were assessed by plaque assay and real-time quantitative PCR. Inactivated samples were subject to three successive passages on permissive tissue culture to exclude the presence of replication-competent viral particles. RESULTS: Inactivation of infectious viral particles in spiked plasma units below the limit of detection was achieved by amotosalen/UVA light treatment with a mean log reduction of >3·32 ± 0·2. Passaging of inactivated samples on permissive tissue showed no viral replication even after 9 days of incubation and three passages, confirming complete inactivation. The treatment also inhibited NAT detection by nucleic acid modification with a mean log reduction of 2·92 ± 0·87 PFU genomic equivalents. CONCLUSION: Amotosalen/UVA light treatment of SARS-CoV-2 spiked human plasma units efficiently and completely inactivated >3·32 ± 0·2 log of SARS-CoV-2 infectivity, showing that such treatment could minimize the risk of transfusion-related SARS-CoV-2 transmission.


Assuntos
Furocumarinas/farmacologia , Plasma/virologia , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/efeitos da radiação , Terapia Ultravioleta , Inativação de Vírus , COVID-19/prevenção & controle , COVID-19/transmissão , Humanos , Reação Transfusional/prevenção & controle , Resultado do Tratamento
12.
J Med Virol ; 93(8): 5167-5172, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33174620

RESUMO

Monitoring of alphatorquevirus (torque teno virus [TTV]) DNA in plasma may prove to be useful to assess the net state of immune competence following allogeneic hematopoietic stem cell transplantation (allo-HSCT). There are scarce data published on the prevalence of beta (torque teno mini virus [TTMV]) and gammatorqueviruses (torque teno midi virus [TTMDV]) and, in particular, on the dynamics of anelloviruses in allo-HSCT patients. Twenty-five allo-HSCT recipients with available plasma specimens obtained before conditioning and after engraftment were included. Degenerated primers targeting a highly conserved genomic sequence across all anelloviruses were designed for genomic amplification and high-throughput sequencing. Co-detection of TTV, TTMV, and TTMDV both in pre-transplant and post-engraftment plasma specimens was documented in more than two-thirds of patients. The use of quantitative real-time polymerase chain reaction (PCR) assays targeting TTMV and TTMDV in addition to TTV may add value to TTV-specific PCR assays in the inference of the net state of immunosuppresion or immune competence in this clinical setting.


Assuntos
Anelloviridae/genética , Infecções por Vírus de DNA/virologia , Transplante de Células-Tronco Hematopoéticas , Adulto , Idoso , Anelloviridae/classificação , Anelloviridae/isolamento & purificação , Infecções por Vírus de DNA/sangue , Infecções por Vírus de DNA/imunologia , DNA Viral/sangue , DNA Viral/genética , Feminino , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Plasma/virologia , Transplante Homólogo
13.
J Med Virol ; 93(8): 4780-4785, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33200412

RESUMO

Human parvovirus B19 (B19V) and human parvovirus 4 (PARV4) are known to infect humans and transmit through contaminated blood and blood products. Globally, three genotypes of B19V, as well as PARV4, have been identified, respectively. The existence of different B19V genotypes in Chinese plasma donors has been investigated, however, the data regarding PARV4 were not available. The main objective of this study is to identify the genotypes of PARV4 circulating in Chinese plasma donors. By using a duplex quantitative polymerase chain reaction assay adapted for all genotypes of B19V and PARV4, 78 source plasma pools for fractionation were screened and quantified. Results showed that positive rates of B19V and PARV4 DNA in plasma pool samples were 25.64% and 14.10%, respectively. PARV4 sequences in two positive samples were next genotyped, and these two sequences belonged to PARV4 genotypes 1 and 2, respectively. In conclusion, the data present demonstrate the existence of PARV4 genotypes 1 and 2 in Chinese plasma donors for the first time and also show the relatively lower prevalence and level of PARV4 DNA in Chinese plasma donors in comparison with that of B19V DNA.


Assuntos
Doadores de Sangue , Genótipo , Infecções por Parvoviridae/epidemiologia , Parvovirus/classificação , Parvovirus/genética , Plasma/virologia , China , Humanos , Infecções por Parvoviridae/transmissão , Parvovirus/isolamento & purificação , Filogenia , Prevalência
14.
J Extracell Vesicles ; 10(2): e12040, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33363711

RESUMO

Extracellular vesicles (EVs) are emerging fundamental players in viral infections by shuttling viral components, mediating immune responses and likely the spread of the virus. However, the obstacles involved in purifying EVs and removing contaminating viral particles in a reliable and effective manner bottlenecks the full potential for the development of clinical and diagnostic treatment options targeting EV. Because of the similarities in size, density, membrane composition and mode of biogenesis of EVs and virions there are no standardized approaches for virus-removal from EV preparations yet. Functional EV studies also require EV samples that are devoid of antibody contaminants. Consequently, the study of EVs in virology needs reliable and effective protocols to purify EVs and remove contaminating antibodies and viral particles. Here, we established a protocol for EV purification from hepatitis B virus (HBV)-containing plasma by a combination of size-exclusion chromatography and affinity-based purification. After purification, EV samples were free of virus-sized particles, HBV surface antigen, HBV core antigen, antibodies or infectious material. Viral genomic contamination was also decreased following purification. By using appropriate antibodies and size parameters, this protocol could potentially be applied to purification of EVs from other viral samples. In summary, we established a fast, reproducible and robust approach for the removal of HBV from EV preparations. Looking forward to the point of purifying EVs from clinical samples, this method should enable studies shedding light on the underlying mechanisms of EVs in viral infections and their diagnostic and prognostic potential.


Assuntos
Cromatografia de Afinidade/métodos , Cromatografia em Gel/métodos , Vesículas Extracelulares/fisiologia , Vírus da Hepatite B/fisiologia , Hepatite B/metabolismo , Plasma/metabolismo , Vesículas Extracelulares/química , Vesículas Extracelulares/virologia , Hepatite B/patologia , Hepatite B/virologia , Humanos , Plasma/virologia
15.
PLoS One ; 15(12): e0243967, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33351831

RESUMO

The ongoing coronavirus disease 2019 (COVID-19) pandemic emerged in December 2019. Convalescent plasma represents a promising COVID-19 treatment. Here, we report on the manufacturing of a plasma-based product containing antibodies specific to SARS-CoV-2 obtained from recently recovered COVID-19 patients. Convalescent plasma donors were screened as follows: 1) previously confirmed SARS-CoV-2 infection (by real-time PCR (RT-PCR)); 2) a subsequent negative PCR test followed by a 2-week waiting period; 3) an additional negative PCR test prior to plasmapheresis; and 4) confirmation of the presence of SARS-CoV-2 specific antibodies. Convalescent plasma was stored fresh (2-6°C) for up to 5 days or frozen (-30°C) for long-term storage. Donor peripheral blood and final plasma product were assayed for binding antibodies targeting the SARS-CoV-2 S-protein receptor-binding domain (RBD) and their titers measured by an enzyme-linked immunosorbent assay (ELISA). We performed 72 plasmaphereses resulting in 248 final products. Convalescent plasma contained an RBD-specific antibody titer (IgG) ranging from 1:100 to 1:3200 (median 1:800). The titer was congruent to the titer of the blood (n = 34) before collection (1:100-1:6400, median 1:800). Levels of IL-8 and LBP of donors were slightly increased. Therapeutic products derived from a human origin must undergo rigorous testing to ensure uniform quality and patient safety. Whilst previous publications recommended RBD-specific binding antibody titers of ≥ 1:320, we selected a minimum titer of 1:800 in order to maximize antibody delivery. Production of highly standardized convalescent plasma was safe, feasible and was readily implemented in the treatment of severely ill COVID-19 patients.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/imunologia , COVID-19/terapia , Adolescente , Adulto , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/epidemiologia , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunização Passiva , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Pandemias , Plasma/imunologia , Plasma/virologia , Plasmaferese/métodos , SARS-CoV-2/imunologia , Doadores de Tecidos , Adulto Jovem , Soroterapia para COVID-19
16.
J Transl Med ; 18(1): 412, 2020 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-33138836

RESUMO

The latest outbreak of pneumonia caused by SARS-CoV-2 presents a significant challenge to global public health and has a major impact on clinical microbiology laboratories. In some situations, such as patients in coma condition, the oropharyngeal or nasopharyngeal sampling is seldom feasible, and blood sampling could be an alternative. In the current article, a comprehensive literature search has been conducted for detecting coronavirus disease 2019 (COVID-19) using plasma or serum samples. To date, twenty-six studies have used SARS-CoV-2 nucleic acid in plasma or serum (RNAaemia) to diagnose COVID-19. The pros and cons are discussed in this article. While the detection of SARS-CoV-2 viral load in respiratory specimens is commonly used to diagnose COVID-19, detecting SARS-CoV-2 RNA in plasma or serum should not lose sight and it could be considered as an alternative diagnostic approach.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , RNA Viral/sangue , Betacoronavirus , COVID-19 , Teste para COVID-19 , Infecções por Coronavirus/sangue , Humanos , Pandemias , Plasma/virologia , Pneumonia Viral/sangue , SARS-CoV-2 , Soro/virologia , Carga Viral
17.
Nature ; 587(7835): 588-593, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33239800

RESUMO

The quantum spin properties of nitrogen-vacancy defects in diamond enable diverse applications in quantum computing and communications1. However, fluorescent nanodiamonds also have attractive properties for in vitro biosensing, including brightness2, low cost3 and selective manipulation of their emission4. Nanoparticle-based biosensors are essential for the early detection of disease, but they often lack the required sensitivity. Here we investigate fluorescent nanodiamonds as an ultrasensitive label for in vitro diagnostics, using a microwave field to modulate emission intensity5 and frequency-domain analysis6 to separate the signal from background autofluorescence7, which typically limits sensitivity. Focusing on the widely used, low-cost lateral flow format as an exemplar, we achieve a detection limit of 8.2 × 10-19 molar for a biotin-avidin model, 105 times more sensitive than that obtained using gold nanoparticles. Single-copy detection of HIV-1 RNA can be achieved with the addition of a 10-minute isothermal amplification step, and is further demonstrated using a clinical plasma sample with an extraction step. This ultrasensitive quantum diagnostics platform is applicable to numerous diagnostic test formats and diseases, and has the potential to transform early diagnosis of disease for the benefit of patients and populations.


Assuntos
Técnicas Biossensoriais/métodos , Diagnóstico Precoce , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/genética , Nanodiamantes/química , RNA Viral/sangue , Avidina/química , Técnicas Biossensoriais/instrumentação , Biotina/química , Fluorescência , Ouro/química , HIV-1/isolamento & purificação , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Microfluídica/instrumentação , Microfluídica/métodos , Micro-Ondas , Técnicas de Amplificação de Ácido Nucleico , Papel , Plasma/virologia , Teoria Quântica , Sensibilidade e Especificidade , Imagem Individual de Molécula , Temperatura
18.
Int J Mol Sci ; 21(21)2020 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-33121182

RESUMO

Merkel cell polyomavirus (MCPyV) viral protein 1 (VP1) is the capsid protein that mediates virus attachment to host cell receptors and is the major immune target. Given the limited data on MCPyV VP1 mutations, the VP1 genetic variability was examined in 100 plasma and 100 urine samples from 100 HIV+ individuals. Sequencing of VP1 DNA in 17 urine and 17 plasma specimens, simultaneously MCPyV DNA positive, revealed that 27 samples displayed sequences identical to VP1 of MCC350 strain. VP1 from two urine specimens had either Thr47Ser or Ile115Phe substitution, whereas VP1 of one plasma contained Asp69Val and Ser251Phe substitutions plus deletion (∆) of Tyr79. VP1 DNA in the remaining samples had mutations encoding truncated protein. Three-dimensional prediction models revealed that Asp69Val, Ser251Phe, and Ile115Phe caused neutral effects while Thr47Ser and Tyr79∆ produced a deleterious effect reducing VP1 stability. A549 cells infected with urine or plasma samples containing full-length VP1 variants with substitutions, sustained viral DNA replication and VP1 expression. Moreover, medium harvested from these cells was able to infect new A549 cells. In cells infected by samples with truncated VP1, MCPyV replication was hampered. In conclusion, MCPyV strains with unique mutations in the VP1 gene are circulating in HIV+ patients. These strains display altered replication efficiency compared to the MCC350 prototype strain in A549 cells.


Assuntos
Substituição de Aminoácidos , Proteínas do Capsídeo/química , Infecções por HIV/virologia , Poliomavírus das Células de Merkel/fisiologia , Infecções por Polyomavirus/virologia , Células A549 , Adulto , Idoso , Proteínas do Capsídeo/genética , Estudos Transversais , Feminino , Infecções por HIV/sangue , Infecções por HIV/urina , HIV-1/patogenicidade , Humanos , Masculino , Poliomavírus das Células de Merkel/genética , Pessoa de Meia-Idade , Modelos Moleculares , Plasma/virologia , Infecções por Polyomavirus/sangue , Infecções por Polyomavirus/genética , Infecções por Polyomavirus/urina , Conformação Proteica , Estabilidade Proteica , Urina/virologia , Replicação Viral , Adulto Jovem
19.
Blood Transfus ; 18(6): 454-464, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33000752

RESUMO

BACKGROUND: As a pooled donor blood product, cryoprecipitate (cryo) carries risks of pathogen transmission. Pathogen inactivation (PI) improves the safety of cryoprecipitate, but its effects on haemostatic properties remain unclear. This study investigated protein expression in samples of pathogen inactivated cryoprecipitate (PI-cryo) using non-targeted quantitative proteomics and in vitro haemostatic capacity of PI-cryo. MATERIALS AND METHODS: Whole blood (WB)- and apheresis (APH)-derived plasma was subject to PI with INTERCEPT® Blood System (Cerus Corporation, Concord, CA, USA) and cryo was prepared from treated plasma. Protein levels in PI-cryo and paired controls were quantified using liquid chromatography-tandem mass spectrometry. Functional haemostatic properties of PI-cryo were assessed using a microparticle (MP) prothrombinase assay, thrombin generation assay, and an in vitro coagulopathy model subjected to thromboelastometry. RESULTS: Over 300 proteins were quantified across paired PI-cryo and controls. PI did not alter the expression of coagulation factors, but levels of platelet-derived proteins and platelet-derived MPs were markedly lower in the WB PI-cryo group. Compared to controls, WB (but not APH) cryo samples demonstrated significantly lower MP prothrombinase activity, prolonged clotting time, and lower clot firmness on thromboelastometry after PI. However, PI did not affect overall thrombin generation variables in either group. DISCUSSION: Data from this study suggest that PI via INTERCEPT® Blood System does not significantly impact the coagulation factor content or function of cryo but reduces the higher MP content in WB-derived cryo. PI-cryo products may confer benefits in reducing pathogen transmission without affecting haemostatic function, but further in vivo assessment is warranted.


Assuntos
Proteínas Sanguíneas/efeitos dos fármacos , Proteínas Sanguíneas/efeitos da radiação , Segurança do Sangue , Infecções Transmitidas por Sangue/prevenção & controle , Patógenos Transmitidos pelo Sangue/efeitos dos fármacos , Patógenos Transmitidos pelo Sangue/efeitos da radiação , Viabilidade Microbiana , Plasma/efeitos dos fármacos , Plasma/efeitos da radiação , Inativação de Vírus , Remoção de Componentes Sanguíneos , Plaquetas/química , Preservação de Sangue , Proteínas Sanguíneas/análise , Micropartículas Derivadas de Células/enzimologia , Criopreservação , Furocumarinas/farmacologia , Furocumarinas/efeitos da radiação , Humanos , Viabilidade Microbiana/efeitos dos fármacos , Viabilidade Microbiana/efeitos da radiação , Fotoquímica , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/efeitos da radiação , Plasma/microbiologia , Plasma/virologia , Tromboelastografia , Trombina/biossíntese , Tromboplastina/análise , Raios Ultravioleta , Inativação de Vírus/efeitos dos fármacos , Inativação de Vírus/efeitos da radiação
20.
Am J Pathol ; 190(11): 2290-2303, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32795424

RESUMO

Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2, has spread globally, and proven treatments are limited. Transfusion of convalescent plasma collected from donors who have recovered from COVID-19 is among many approaches being studied as potentially efficacious therapy. We are conducting a prospective, propensity score-matched study assessing the efficacy of COVID-19 convalescent plasma transfusion versus standard of care as treatment for severe and/or critical COVID-19. We present herein the results of an interim analysis of 316 patients enrolled at Houston Methodist hospitals from March 28 to July 6, 2020. Of the 316 transfused patients, 136 met a 28-day outcome and were matched to 251 non-transfused control COVID-19 patients. Matching criteria included age, sex, body mass index, comorbidities, and baseline ventilation requirement 48 hours from admission, and in a second matching analysis, ventilation status at day 0. Variability in the timing of transfusion relative to admission and titer of antibodies of plasma transfused allowed for analysis in specific matched cohorts. The analysis showed a significant reduction (P = 0.047) in mortality within 28 days, specifically in patients transfused within 72 hours of admission with plasma with an anti-spike protein receptor binding domain titer of ≥1:1350. These data suggest that treatment of COVID-19 with high anti-receptor binding domain IgG titer convalescent plasma is efficacious in early-disease patients.


Assuntos
Betacoronavirus/patogenicidade , Infecções por Coronavirus/mortalidade , Plasma/imunologia , Pneumonia Viral/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Transfusão de Componentes Sanguíneos/métodos , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/terapia , Infecções por Coronavirus/virologia , Feminino , Humanos , Imunização Passiva/mortalidade , Masculino , Pessoa de Meia-Idade , Pandemias , Plasma/virologia , Pneumonia Viral/diagnóstico , Pneumonia Viral/virologia , Estudos Prospectivos , SARS-CoV-2 , Soroterapia para COVID-19
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...